SLC Safety Relay SLC-2A1B220J Safety Relay

■Features:

●Applicable to emergency stop switch, safety door,safety switch.

●Safety relay operates with AC85-260V wide powersupply.

●Dual-channel operation mode, passive contact input,reset switch is equipped with contact.

●2 sets of normally open safety contacts output inseries, 1 set of normally closed auxiliary contacts output in parallel.

●Power indicator and channel 1 and channel 2 statusindicator.

●The number of safety contacts can be increased bymeans of an expansion module.

●Circuits with self-monitoring redundant circuits.

●The safety function of the relay can be automaticallydetected by correct opening and closing during each switching cycle.

●Safety level up to 4, the safety function remainsactive even if one of the components is damaged.

●Connected with emergency stop switches, safety gates,and safety switches, it can monitor the controlled equipment at all times,constituting a safer protection system.

●22.5mm wide, GIN rail mounting.

●Conforms to standards EN60947-5-1, EN61000-6-2,EN61000-6-3, EN60204-1, ENISO13849-1.

 

Online Consultation

Type

Parameter

Model

SLC-2A1B220J

Power supply

AC85-260V

Power consumption

3W

Input mode

Two passive contact inputs

Input protection

Dual channels with contact short-circuit detection

Switching Capacity

AC-15,2A/250V: DC-13,3A/24V according to EN60947-5-1

Output voltage

DC24V 200mA

Output

2 normally open safety contacts and 1 normally closed auxiliary contact

Contact fuse protection

4A T or 6A F

Manual reset time

Max.100ms

Automatic reset time

Max.50ms

Release buffer time

Max.10ms

Ambient temperature

Operating: -10 to +50°C (non-freezing), storage: -25 to +55°C

Anti-vibration

Vibration frequency: 10-30Hz, amplitude: 0.35mm, X, Y, Z direction each 2 hours

Radiation-resistant electromagnetic fields

Withstand radiated electromagnetic field interference with a field strength of 1V/m

Antistatic discharge

Capable of withstanding electrostatic discharge interference with a voltage of 2KV.

Fast transient resistance

Capable of withstanding electrical fast transient pulse group interference at 1KV.

Working life

Internal relay not less than 10 million cycles, electrical 30,000 hours

Maximum wire cross-section size

0.2-2.5mm

Terminal torque

0.5Nm

Dimensions (L×W×H)

100×22.5×113mm

IP rating

IEC IP54

Shell material

PA nylon

SLC Safety Relay ( 0 )