EN
GAM General Purpose Measuring Light Curtain GAM General Purpose Measuring ...

■Features

●Forhigh-precision inspection and measurement in industrial automation systems.Including in-line inspection, accuracy correction, void detection, edge andcenter positioning, tension control, parts counting, and in-line product sizeand shape inspection and similar inspection and measurement as above.

●Exteriordimensions: 35 mm x 50 mm.

●High resolution:optical axis spacing as low as 10 mm.

●Multiple options:Measuring height from 120 mm to 6360 mm, optical axis number from 4 to 160, canbe selected according to the monitoring range used.

●Performanceguarantee: external amplifier, modulated light source, synchronized scanningmethod, strong resistance to external interference ability easy to install anduse.

●Standard typeprotection grade IP66, waterproof type protection grade up to IP68.

● High-qualityprotection: high-quality protective structure and vibration resistance, so thatthe light curtain can be used in harsh environments and heavy equipment forreliable use.

● Main signaloutput: analog output (4-20mA or 1-5VDC output), RS485 communication output.

●Auxiliary signaloutput is normally open or normally closed relay contact output, which can beconnected to any load.

●Digital tube andred, yellow and green color indicators enable users to accurately, intuitivelyand quickly display the status of the measured object.

●High reactionspeed, the minimum reaction time is only 2ms.

Online Consultation

Parameters and model

GAM10series

GAM20series

GAM30series

GAM40series

GAM80series

Number of optical axes

1624 to 160

810to

160

46to

160

46to

160

48to

72

Beam pitch

10mm

20mm

30mm

40mm

80mm

Minimum protected object

φ15mm

φ25mm

φ35mm

φ45mm

φ85mm

Protection height

Beam pitch ×number of optical axes-1

Protective range

A series:0-3mB series:0-6mC series:0-12mD series:0-20m

Power supply voltage

DC24V±10%

Power consumption

8W

Response time

3-32ms

Output

Analog

4-20mA1-5VDC

Communication output

RS485

Auxiliary output

Output form

Relay passive contact output

Output status

Normally open or normally closed output state

Contact capacity

2A/250V30VDC

Protection

Output short-circuit protection

Indicator light

Transmitter

Yellow light on, power on

Receiver

Dual-color red and green indicators, unshaded (green), shaded (red)

Digital display*

Display of optical axis blocking position, display range 0-G0

Light-resistant environment

Sunlight: 10,000 Lx, white woven light: 3000 Lx

Ambient Temperature

-25 to +70° Celsius (note no condensation, freezing)

Ambient Humidity

35-95RH

Anti-vibration

Frequency: 10-55Hz, amplitude: 0.75mm, 2 hours in each direction X, Y, Z

Anti-impact

Acceleration 300m/s, 2 hours in each direction X, Y, Z

Insulation resistance

AC1000V, 50/60Hz, 1 minute

Dielectric strength

DC500V,20MΩ

Connection method

With special connecting cable, 5-pole emitter, 9-pole light receiver

Shell material

Protective housing: Aluminum alloy End cap: ABS engineering plastic Bracket: Cold rolled steel plate

Protective structure

Standard type:IEC IP65